This commit is contained in:
lucasdpt
2026-06-14 02:07:47 +02:00
parent 398e1e6ddf
commit 0129d81bd4
2475 changed files with 553889 additions and 553884 deletions
+27 -27
View File
@@ -1,27 +1,27 @@
#Settings for configuring Large Heat Generators
[large_heat_generator]
#Amount of energy in Joules the Large Heat Generator produces per tick. largeHeatGeneration + largeHeatGenerationLava * lavaSides + largeHeatGenerationNether. Note: lavaSides is how many sides are adjacent to lava, this includes the block itself if it is lava logged allowing for a max of 81 "sides".
# Default: 1000
# Range: 0 ~ 9223372036854775807
largeHeatGeneration = 1000
#Multiplier of effectiveness of Lava that is adjacent to the Large Heat Generator.
# Default: 350
# Range: 0 ~ 113868790578454022
largeHeatGenerationLava = 350
#Add this amount of Joules to the energy produced by a large heat generator if it is in an 'ultrawarm' dimension, in vanilla this is just the Nether.
# Default: 750
# Range: 0 ~ 9223372036854775807
largeHeatGenerationNether = 750
#The capacity in mB of the fluid tank in the Large Heat Generator.
# Default: 240000
# Range: > 1
tankCapacity = 240000
#The amount of lava in mB that gets consumed to transfer largeHeatGeneration Joules to the Large Heat Generator.
largeHeatGenerationFluidRate = 10
#Settings for configuring Large Gas-Burning Generators
[gas_generator]
#The capacity in mB of the chemical tank in the Large Gas-Burning Generator.
# Default: 180000
# Range: 1 ~ 9223372036854775807
tankCapacity = 180000
#Settings for configuring Large Heat Generators
[large_heat_generator]
#Amount of energy in Joules the Large Heat Generator produces per tick. largeHeatGeneration + largeHeatGenerationLava * lavaSides + largeHeatGenerationNether. Note: lavaSides is how many sides are adjacent to lava, this includes the block itself if it is lava logged allowing for a max of 81 "sides".
# Default: 1000
# Range: 0 ~ 9223372036854775807
largeHeatGeneration = 1000
#Multiplier of effectiveness of Lava that is adjacent to the Large Heat Generator.
# Default: 350
# Range: 0 ~ 113868790578454022
largeHeatGenerationLava = 350
#Add this amount of Joules to the energy produced by a large heat generator if it is in an 'ultrawarm' dimension, in vanilla this is just the Nether.
# Default: 750
# Range: 0 ~ 9223372036854775807
largeHeatGenerationNether = 750
#The capacity in mB of the fluid tank in the Large Heat Generator.
# Default: 240000
# Range: > 1
tankCapacity = 240000
#The amount of lava in mB that gets consumed to transfer largeHeatGeneration Joules to the Large Heat Generator.
largeHeatGenerationFluidRate = 10
#Settings for configuring Large Gas-Burning Generators
[gas_generator]
#The capacity in mB of the chemical tank in the Large Gas-Burning Generator.
# Default: 180000
# Range: 1 ~ 9223372036854775807
tankCapacity = 180000